+374 43 00 1655

No. 6/1, Griboyedov St., Yerevan, Armenia

+374 99 013 143

No. 6/1, Griboyedov St., Yerevan, Armenia

Hospital Beds

Newborn resuscitation bed Lyona (I2100WPRO)

The basic requirement for therapy and treatment of newborns, and in particular the ones with Low Birth Weight, is to have a temperature-controlled environment. To achieve this goal there are currently many methods which require usage of various devices, among which the most common, other than incubators, are the Infant Warmers. That is to say, open incubators with infrared radiant heating. These are most often used in delivery rooms and in intensive therapy centers. This system, which allows fast and easy access to the newborn, is the most used and efficient method for maintaining both the baby’s body and the bed at an ideal temperature.

Technical Information

  • Apgar timer (1-5-10 min)
  • Phototherapy duration timer
  • Electric controller with three modes: prewarm – manual – baby
  • Skin sensor to control the baby’s body temperature in baby mod e
  • Easy access to the new born through the rotating capability of warmer to both sides
  • Cooling fan installed inside the warmer section for air conditioning
  • Two ceramic heaters to warm the bed and baby
  • Warmer guard to prevent the hand entry to the heater compartment
  • Protective foam to prevent damage to the user’s head
  • X- Ray permeable mattress
  • Butterfly shields and gauges on both sides with polyamide plastic holders
  • Five failure alarms: over temperature, power failure, setting, checking and H/L
  • Holding handle in the main column for easy movement and install required accessories
  • Stand on both sides of the device to place the monitor and pulse oximeter
  • Trend/Rev.Trend, adjustment by means of gas spring
  • Fixed handle for Trend / Rev. Trend, adjustment
  • ABS cover for warmer and mattress platform
  • Tray for holding baby items on the base
  • Electrostatic powder coating
  • Four plastic swivel castors with 2 independent brakes in the front
  • Two oxygen cylinder holders
  • With IV pole holder on both sides
  • LED phototherapy lamps with a wavelength of 465 – 470 nano meter
  • Main power supply 220V – 50 Hz, 24 DC
  • Maximum power output 1200 VA
  • Equipped with a curved IV pole holder
  • LED Light bulb

Dimensions and Basic Information

  • Overall 1200 x 1060 x 1790 (mm)
  • Heater height up to mattress 750mm ± 10mm
  • Trend / Rev. Trend angle +15º / -15º
  • baby mode control range 34.5°C – 37.5°C
  • Angle of warmer module 0°, 30°, 60°, 90° for two ways
  • Accuracy of skin temperature sensor ± 0.1˚ C
  • Max load capacity 40 Kg
  • Bed net weight 110 Kg
  • Safe working load capacity 10 Kg
  • ENVIRONMENTAL TEMPERATURE: Operating range 18°C – 30°C

Standards

  • SO 9001
  • ISO 13485
  • EN ISO 15223-1
  • EN ISO 14971
  • IEC 60601-1
  • IEC 60601-2-21
  • IEC 60601-2-50
  • IEC 62304

Accessories (optional)

  • Two oxygen cylinder holders